Services
User Training and Microscopy Courses
We provide thorough training to all new users of the light microscopy facility. This includes one-on-one instrument training sessions where users learn how to operate microscopes (e.g. confocal or wide-field systems) and practice with their own samples under staff guidance. Additionally, the facility contributes to formal courses on microscopy. For example, we organize and teach in the annual LCAM microscopy courses (e.g. basic and advanced microscopy courses) to educate researchers in fluorescence microscopy fundamentals and advanced techniques. Ongoing workshops and seminars (often in collaboration with microscope manufacturers or research initiatives) are also offered to introduce new imaging technologies or methods. Our goal is to ensure every user is confident and competent in using the microscopes independently and safely.
Consultation and Experimental Design
The light microscopy staff offer consultation services to help plan imaging experiments. This can range from advising on the choice of microscope or technique for a given scientific question, to optimizing imaging parameters (e.g. selecting objective lenses, fluorophores, camera settings, laser lines) for the best results. We assist researchers in designing multidimensional imaging experiments – for instance, planning a live-cell imaging timeline, setting up multi-channel time-lapse recordings, or performing high-content screening. We also help troubleshoot issues such as sample preparation problems or image artifacts. Early consultation can save researchers time by matching their needs to the right technology (for example, determining if super-resolution is required, or if an automated high-content approach is more suitable).
Image Analysis Support
Obtaining data is only part of the imaging workflow; analyzing images is equally important. The facility provides support in image processing and analysis. We maintain analysis workstations with software like Leica LAS X, Huygens Deconvolution, ImageJ/Fiji, and other specialized tools for 3D image analysis or fluorescence quantification. Users can get advice on how to deconvolve images to improve resolution, how to perform colocalization or intensity quantification, and how to handle large 5D datasets. For more advanced analysis needs (such as automated image analysis for high-content screens or custom image analysis pipelines), our team can offer guidance and, in some cases, collaboration to implement solutions.
Collaboration and Advanced Techniques
For projects requiring advanced or non-standard techniques, the light microscopy team is available to collaborate. This might include developing new imaging protocols, beta-testing novel hardware or software, or performing complex techniques like FLIM/FRET, FRAP, photoactivation, or super-resolution imaging beyond the routine scope. We encourage researchers to involve us as collaborators in challenging imaging projects – our staff have expertise in many cutting-edge methods and can actively contribute to the success of such projects. We can also connect users with the wider microscopy network (via LCAM and NL-BioImaging initiatives) for techniques not available in-house, ensuring researchers have access to the latest imaging innovations.
Operator-assisted EM Imaging
Since Electron Microscopy (EM) can be a difficult technique, many of the projects sent to the facility are handled by our EM staff. A project always starts with an intake, deciding if EM is indeed the optimal technique to answer the research question and if so, which EM techniques would be most appropriate. During the intake, we will discuss the imaging requirements (organelle of interest, magnification, number of images, etc.), then acquire the images and provide the data to the researcher. we also discuss what the researcher is expecting from the EM work, what other techniques have been used and what the supposed regions/organelles of interest are. When you come in for the intake, you’re expected to have thought about these questions. For operator-assisted EM imaging, we offer different bundles; full-service packages with a fixed price, that will include all steps necessary to go from sample fixation to EM images.
Our current bundles are:
· TEM, plastic / epon (per 8 samples)
· TEM, negative stain (per 8 samples)
· TEM, immuno-gold (per 4 samples)
· TEM, cryo-vesicles (per 4 samples)
· SEM, dehydrated (per 8 samples)
· SEM, no dehydration (per 8 samples)
With add-ons:
· CLEM (per sample)
· EDS (per run/image)
· Tomography (per tomogram)
Training for Independent EM Use
For researchers who have extensive projects or previous experience with EM, it is possible to be trained to operate the microscopes independently. Trainings consist of an online theoretical introduction (sometimes grouped, about 1 hour), explaining the basic principles of electron microscopy and how to operate our available microscopes, and a practical introduction of a half-day (individual, or per request, with your research partner), providing hands-on explanations on how to best image your samples. Only after demonstrating proficiency, users are allowed to book microscope time for independent use. This ensures both user safety and protection of the sensitive EM instruments.
Development
Electron microscopy encompasses a range of techniques, and choosing the right approach is crucial. We provide consultation on EM project design – advising whether a sample is best examined by TEM or SEM, whether it would benefit from immuno-labeling, or if techniques like CLEM (correlative light and EM) should be employed. If a project requires development of new protocols (for example, trying a novel staining method, or adapting a sample preparation for an unusual specimen), our EM specialists will work closely with the researcher to develop and test the method. We stay updated on the latest EM technologies and can assist in implementing advanced methods such as array tomography (sequential section SEM for 3D volume), freeze-substitution, or 3D electron microscopy using FIB-SEM (focused ion beam SEM), through our network (Nodes – Nemi) if not available in-house. We strive to keep the EM facility at the cutting edge, and part of that is collaborating with researchers on innovative uses of EM in their projects.
Sample Preparation Services
Electron Microscopy (EM) often requires elaborate sample preparation, starting with fixation of the biological samples (tissues, cell pellets, organoids, etc.). Researchers are expected to perform this step themselves, but will be able to receive the necessary EM grade fixative and a protocol appropriate for the type of experiment from us. Depending on what EM technique is chosen, sample preparation can vary. For TEM, samples can be stained as is (negative staining, only for small samples such as vesicles, bacteria, etc.) or embedded in plastic (epon) or gelatine (immuno-gold). After embedding, samples are sectioned ultra-thin and stained when appropriate. Then, samples are ready to be imaged using one of our 120kV TEM’s. SEM samples often need dehydration, which we do using a series of chemical dehydration followed by critical point drying. Samples are then mounted on aluminum stubs, sputter-coated with a thin layer of platinum/palladium and ready for imaging. By entrusting our team with sample prep, researchers can ensure their samples are optimally prepared for high-quality imaging results.
Data Analysis and Interpretation
Acquiring EM images is only part of the service; we also help users interpret the TEM or SEM data. Our staff can guide users in analyzing EM data, such as measuring structures in TEM images, counting gold particles for immunogold quantification, to optimizing images and stitching, or interpreting EDS data. Some actual parts of the analysis are also included in the bundles, such as 3D reconstruction of tomograms, CLEM overlaying and deconvoluting EDS spectra. We ensure that users understand the resolution and potential artifacts of EM, so they can draw accurate conclusions from their images. Ultimately, our goal is to make sure the researcher fully understands the collected data and that accurate conclusions are drawn from the information.
Introductory Courses and Training
The flow cytometry facility requires all users to undergo training before independent instrument use. We organize a monthly introduction seminar covering flow cytometry theory and best practices for both analysis and sorting. After this class, each user receives a practical training session on the specific analyzer or sorter they will use, where they learn startup/shutdown procedures, software operation, compensation setup, gating strategies, and safety considerations. This training ensures that users can confidently run experiments on our flow cytometers and troubleshoot basic issues. Refresher trainings or advanced topic workshops (e.g. on multicolor panel design or spectral flow cytometry) are provided on demand.
Operator-Assisted Cell Sorting
While trained users may operate certain sorters, we recognize that cell sorting can be technically demanding or that some users prefer not to run the sorter themselves. Our flow core operators are available to perform cell sorting as a service. Researchers can simply drop off their samples (or stay to observe) and our experienced staff will run the sort, optimizing the instrument settings for yield, purity, and cell viability. This is especially recommended for high-speed sorts of rare populations or when using novel instruments like the spectral sorter. Operator-assisted sorting is scheduled in advance and incurs an operator fee (see Fees section), but ensures a smooth and reliable sorting process – particularly for complex sorts or BSL-2 safety level sorts that must be done by staff.
Panel Design and Experiment Consultation
Designing a successful flow cytometry experiment (especially with many colors) can be challenging. We offer consultation on panel design, helping researchers choose the right combination of fluorochromes for their targets (taking into account instrument laser/detector configurations and avoiding spectral overlap issues). We also advise on sample preparation (e.g. staining protocols, controls like compensation controls and viability dyes, handling of cells to minimize autofluorescence or clumping). If a project involves sorting, we discuss gating strategies to define the sort populations and post-sort analysis. Our goal is to leverage our expertise to improve the quality of data and save researchers from common pitfalls in flow experiments.
Data Analysis and Software Support
The flow cytometry facility provides resources for analyzing the data generated. We maintain several analysis workstations with popular flow cytometry software such as FlowJo, FCS Express, Cytosplore (for high-dimensional data), and the Amnis IDEAS software for imaging flow cytometry. Users can access these workstations to analyze their FCS files, or request help in performing advanced analyses (for example, high-dimensional data reduction like t-SNE/UMAP, cluster analysis, or creating multi-panel figures). For imaging flow cytometry data, we assist in using the IDEAS software to extract image features and generate graphs. If needed, we can facilitate obtaining a personal software license (e.g. FlowJo portal license) for users who prefer to analyze data on their own computers. Our staff can also advise on data management, storage, and how to set up gating templates or batch analyses to streamline workflow for large experiments.
Specialized Assays and Collaboration
We support a variety of specialized flow cytometry applications. This includes assays like cell cycle analysis, apoptosis assays, calcium flux measurements, fluorescence minus one (FMO) controls for multi-color panels, and rare event analysis (e.g. circulating tumor cells). For spectral flow cytometry, we help set up reference controls and spectral unmixing. For the imaging flow cytometer, we can guide users in combining image analysis with flow data (e.g. calculating morphology metrics for cells in flow). If a research project demands a novel flow cytometry application or significant method development (for instance, customizing a sorter for unique detection or developing a new analysis pipeline), our team is open to collaboration. We have experience collaborating on research projects and can contribute to experimental design, data interpretation, and even manuscript preparation in the realm of cytometry.
Leica SP8 — Zoom Factor Calculator
Computes minimum Zoom Factor, Z‑stack step size, and supporting optics numbers for SP8.
Inputs
Results
Zoom Factor = 2.43
The minimum Zoom Factor for the SP8 = 0.75
Z-Stack Step Size = 0.170µm
Field of View = 76µm x 76µm, XY Pixel Size = 74nm x 74nm, Optical section = 754nm
Lateral Resolution = 139nm, Axial Resolution = 529nm